Belongs to the core devices of the JABLOTRON 100+ security system. This is the smallest control panel for the protection of apartments, family houses and small businesses. It has an integrated LAN communicator and it is fitted with JA-111R module.
The required settings and sizing of the system are programmed through the F-Link software.
The control panel has an integrated LAN communicator that enables data communication with an ARC and the JABLOTRON CLOUD, which enables full use of the MyJABLOTRON application.
The control panel can only be installed by a trained installer with a valid Jablotron certificate.
Type Of Installation | Fixed installation |
---|---|
Nominal control panel voltage / frequency / fuse | ~ 230 V/50 Hz, T200 mA fuse 250 V, 5 x 20 mm |
Operational AC voltage range | ~ 195 V ÷ 250 V |
Electric power/current | max. 23 VA/0.1 A |
Protection class | II. |
Back-up battery | 12 V; 2.6 Ah max. (lead-acid) |
Low battery voltage (fault indication) | ≤11 V |
Maximum battery charging time | 48 ÷ 72 hrs |
BUS voltage/max. voltage ripple (red-black) | 12.0 ÷ 13.8 VDC/± 100 mV |
Max. continuous consumption from the control panel BUS +RJ | 400 mA permanently (1000 mA for 5 minutes) |
12 hours backup (2.6 Ah) | LAN OFF: 125 mA – consumption of modules JA-190X (Y) |
Max. number of sections | 4 |
Max. number of devices | 32 |
Max. number of users | 33 |
Max. number of PG outputs | 4 |
Alarm connection | Jablotron BUS – dedicated wiring |
Alarm system classification | Security grade 2/environmental class II |
@ according to standards | EN 50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3, EN50131-10, EN 50136-1, EN 50136-2 |
@ environment | indoor general |
@ operational temperature/humidity | -10 °C to +40 °C, relative humidity 75% no condensation |
@ power | Type A – primary supply with a charged backup battery |
@ event history | approx. 7 million latest events, incl. date and time |
@ system reaction to communication loss | Fault or tamper – according to the pre-set profile |
@ reaction to invalid code entry | After 10 wrong code entries a tamper alarm is triggered and according to the selected profile it blocks all control devices for 10 min |
@ ATS classification | Supported ATS classes: SP2 – SP 5, DP2 – DP3 |
@ ATS transmission protocols | JABLO IP, SIA IP, Contact ID, JABLO SMS |
@ ATC protection against substitution and data protection | Jablotron protocol: Proprietary AES encryption with minimum 128 bit key |
LAN communicator | Ethernet interface CAT 5 (RJ-45) |
Dimensions | 268 x 225 x 83 mm |
Weight | 1450 g |
Basic parameters of the JA-111R module | 868.1 MHz, <25 mW, GFSK < 80 kHz |
Radio emissions | ETSI EN 300 220-2 (R module) |
EMC | EN 50130-4, EN 55022, ETSI EN 301 489-7, ETSI EN 301 489-3 |
Electric safety | EN 60950-1 |
Operational conditions | ERC REC 70-03, ERC DEC (98) 20 |
Certification body | TREZOR TEST |