JA100-BUS 116H

JA-116H BUS expander – 16 inputs

Bus expander is used for powering and connecting up to 16 detectors with contact outputs. It is possible to install the module straight into the JA-106K control panel.

 

Technical Specifications

Additional information

Power Supply

12 V (9 … 15 V)

Current consumption (all outputs turned on)

25 mA
Warning: the consumptions of the detectors connected to the +U and GND terminals have to be added to the system power backup calculation.

Maximum acceptable load of one output from +U and GND

100 mA

Maximum acceptable load of all outputs from +U and GND

4 x 100 mA

Dimensions

102 x 66 x 20 mm

Weight

80 g

Classification

Security grade 2/Environmental class II

According To

EN 50131-1, EN 50131-3, T014 (INCERT)
(valid when placed into a tamper-protected housing certified for no less then security grade 2/env. class II)

loop inputs parameters

single/double balanced

number of detectors in one loop

max. 5

input balancing (optional)

1k, 2k2, 3k3, 4k7, 5k6, 10k

recomended installation boxes

JA-106K, PLV-CP-M, JA-194PL

operational environment

II., indoor general

operational temperature range

-10 to +40 °C

operational humidity

75 % RH, no condensation

certification body

Trezor Test, ANPI

Also complies with

EN 50130-4, EN 55022